IEC 62304 in Practice: Medical Device Software Life Cycle
The medical device software life cycle under IEC 62304, with safety classes, integration with ISO 14971 and ISO 13485, and cybersecurity.
- Duration
- 16 hours
- Format
- Live online
- Certification
- HSC Global
About the course
A complete course on ABNT NBR IEC 62304, clause by clause, focused on how the requirements apply in practice to embedded software, software as a medical device (SaMD) and connected apps. A practical case, a meter, runs through the whole course to show how each requirement appears in the software life cycle. The course also covers what is under discussion in the new revision of IEC 62304.
What you will learn
Module 01IEC 62304 scope and safety classification (A, B, C)
Module 02The medical software development life cycle
Module 03Planning, requirements, architecture and detailed design
Module 04Implementation, verification and configuration management
Module 05Maintenance, problem resolution and SOUP
Module 06Integration with ISO 14971 and ISO 13485
Module 07ANVISA, FDA (pre-market) and MDR expectations
Learning objective
Equip professionals to interpret and apply the requirements of IEC 62304 throughout the medical device software life cycle: safety classification, development, risk management, cybersecurity, verification, release and maintenance. The course also shows what Anvisa, Inmetro, certification bodies and auditors expect to find.
Who this course is for
Software engineers and developers
System architects
Quality professionals
Regulatory Affairs professionals
R&D managers
Consultants and auditors working with SaMD, SiMD and software embedded in medical devices
Your instructor

Laura de Pauli
Mechanical Engineer specialising in Regulatory Affairs, with 14 years' experience in technical product evaluation, IEC standards and ANVISA regulatory processes. Mechanical Engineer specialising in Regulatory Affairs, with 14 years' experience in technical product evaluation and regulatory affairs. Extensive experience in product conception and design complying with ISO 14971 Risk Management, IEC 62366 Usability Engineering, IEC 62304 Software Life Cycle, and the IEC 60601 series on Basic Safety and Essential Performance of Medical Electrical Equipment. Works in conformity assessment under the Inmetro process, covering a wide range of products such as medical electrical equipment, needles, syringes and infusion sets, with established experience in Anvisa, Anatel and Dimel regulatory processes. Experienced in quality management systems complying with standards such as ISO/IEC 17025 and ISO 13485, and an MDSAP (Medical Device Single Audit Program) Lead Auditor.